Vortex Tube Cooler-Testing Statistics

  • Vortex Tube Cooler-Testing Statistics
STC-V1LD
Vertical Spiral Oil Mist Tube
Air temperature15°C
Pressure Air introduced in total
100%
Cold air in total
43%~100%
Temperature of cold air
(Air Volume43%)
cold air
temperature difference
4kgf/cm2 195L/min 65~180L/min -25.4°C 40.4°C
5kgf/cm2 225L/min 75~210 /min -28.3°C 43.3°C
6kgf/cm2 255L/min 85~240L/min -31.5°C 46.5°C
7kgf/cm2 285L/min 95~270L/min -34.1°C 49.1°C
8kgf/cm2 315L/min 105~300L/min -37.4°C 52.4°C
STC-BW2/BW1/BW1L
Testing Statistics (Vast Air)
Air temperature 28°C
Pressure Air introduced in total
100%
Cold air in total
65%~100%
Temperature of cold air
(Air Volume65%)
cold air
temperature difference
4 kgf/cm2 460L/min 315~460L/min -3.7°C 31.7°C
5 kgf/ cm2 510L/min 330~510 L/min -5.5°C 33.5°C
6 kgf/ cm2 560L/min 360~560 L/min -7.3°C 35.3°C
7 kgf/ cm2 610L/min 395~610 L/min -9.1°C 37.1°C
8kgf/ cm2 655L/min 425~655L/min -10.9°C 38.9°C
STC-BW2D Testing Statistics (Vast Air)
Air temperature 28°C
Pressure Air introduced in total
100%
Cold air in total
57%~100%
Temperature of cold air
(Air Volume65%)
cold air
temperature difference
4 kgf/cm2 510L/min 295~510L/min -4.2°C 32.2°C
5 kgf/ cm2 540L/min 310~540 L/min -6.3°C 34.3°C
6 kgf/ cm2 570L/min 325~570 L/min -8.4°C 36.4°C
7 kgf/ cm2 595L/min 345~595 L/min -10.5°C 38.5°C
8kgf/ cm2 625L/min 360~625L/min -12.6°C 40.6°C
STC-V1/STC-V2/STC-V1L/STC-V2D
Testing Statistics
Environment temperature 30 °C /Air temperature 27.5 °C
Pressure Air introduced in total
100%
Cold air in total
100%
Temperature
OfCold Air
(Air Volume45%)
(RoomTemper Ature)
cold air
temperature difference
cold air
temperature difference
4 kgf/cm 2 175L /min 80~ 175L /min - 5.8 °C 35.8°C 33.3°C
5 kgf/ cm 2 200L /min 90~ 200 L /min - 8.5°C 38.5°C 36°C
6 kgf/ cm 2 225L /min 100~ 225 L /min - 11.2 °C 41.2°C 38.7°C
7 kgf/ cm 2 250L /min 110~ 250 L /min - 13.8°C 43.8°C 41.3°C
8kgf/ cm 2 275L /min 120~ 275L /min - 16.4 °C 46.4°C 43.9°C